This guide introduces the Ideal Logic Combi 24, a compact, efficient wall‑mounted boiler designed for modern homes. It highlights key features, safety, and performance, ensuring users understand installation, operation, and maintenance for reliable heating. The manual covers compliance, the united kingdom.
Key Features and Specifications
The Ideal Logic Combi 24 delivers a 24 kW output in a compact, wall‑mounted design, ideal for tight spaces. It is a condensing boiler with an efficiency rating of up to 94 % (A++), reducing energy bills and emissions. The unit incorporates a digital thermostat and a 7‑day programmable timer, allowing precise temperature control and scheduling. A quiet‑mode function keeps noise below 48 dB(A) for bedroom use. Safety is enhanced by an integrated pressure switch, a low‑water cut‑off, and a flame failure protection system that automatically shuts the boiler if the flame fails to ignite. The control panel features a back‑lit LCD display, intuitive touch controls, and a fault‑code indicator for quick diagnostics. The boiler supports a 0.5 kW to 4 kW heating range, with a 0.5 kW water heating range, making it suitable for small to medium households. The stainless‑steel heat exchanger ensures durability and corrosion resistance. The Combi 24 meets UK regulations, including the Energy Saving Trust’s 2019 guidelines and the UK’s CE marking for safety and environmental compliance.
- Integrated 3‑way valve for simultaneous heating and hot water.
- High‑pressure output up to 1.5 bar for efficient distribution.
- Low‑water cut‑off at 0.5 bar to protect the system.
- Smart‑connect compatibility for remote monitoring.
- Eco‑mode reduces boiler cycling for quieter operation.
All components comply with UK safety standards and are CE marked.
Trusted !

Installation Requirements and Setup
The Ideal Logic Combi 24 requires a dedicated 230 V, 50 Hz supply with a minimum 16 A circuit and a residual current device (RCD) for safety. The boiler must be mounted on a stable wall surface, 0.5 m above floor level, with a 30 cm clearance on all sides for ventilation. A 1.5 m long, 1.5 mm² copper pipe is recommended for the heating loop, and a 1.0 mm² pipe for the domestic hot water loop. The unit must be connected to a 1.5 kW or higher pressure‑rated boiler manifold. A 0.5 bar low‑water cut‑off valve and a 1.5 bar pressure relief valve are mandatory. The boiler’s condensate line should be routed to a suitable drain or condensate pump, ensuring a 5 cm drop per metre. The control panel requires a 5 V DC power supply for the thermostat, which can be wired directly or via the integrated 12 V supply. The installation must comply with BS 7671 (IET Wiring Regulations) and local council guidelines. After mounting, the boiler should be left to settle for 24 hours before first use. The user should then perform a pressure test, ensuring the system reaches 1.0 bar at 60 °C. Finally, the boiler’s digital display will guide the user through the initial programming of the thermostat and timer settings.
The boiler’s control interface supports remote monitoring via the Ideal Logic app, allowing users to view temperature, energy consumption, and fault logs from smartphones or tablets. Users can receive push notifications for maintenance reminders or readings, ensuring proactive care and optimal performance!!!

Safety Instructions and Precautions
Before installing the Ideal Logic Combi 24, ensure the power supply is disconnected and the circuit breaker is switched off. The boiler must be installed on a stable, non‑metallic surface, 0.5 m above the floor, with a minimum 30 cm clearance on all sides for proper ventilation. All electrical connections should be performed by a qualified electrician and must comply with BS 7671 (IET Wiring Regulations). The condensate pipe must be routed to a suitable drain or condensate pump, maintaining a 5 cm drop per metre to prevent back‑flow. The boiler’s pressure relief valve should be set to 1.5 bar, and the low‑water cut‑off valve to 0.5 bar. After mounting, allow the unit to settle for 24 hours before first use. Perform a pressure test, ensuring the system reaches 1.0 bar at 60 °C. Never operate the boiler with a damaged or loose pipe connection, as this can cause leaks or overheating. Keep the area around the boiler free of flammable materials and ensure adequate ventilation. Do not attempt to repair or modify the boiler yourself; contact a licensed technician for any maintenance or fault. Regularly inspect the boiler for signs of corrosion, leaks, or unusual noises, and report any issues immediately to a qualified service provider.
Always keep the user manual in a readily accessible location for reference during operation and maintenance.
The boiler’s fault‑code list quickly identifies issues!!!

Operation Modes and Settings
The Ideal Logic Combi 24 offers three primary operation modes: Eco, Comfort, and Boost. In Eco mode the boiler prioritises energy efficiency, running at a lower temperature and cycling more frequently to minimise consumption. Comfort mode delivers a higher water temperature for instant hot water and a warmer heating output, suitable for colder periods. Boost mode temporarily increases the boiler’s output for a short period, useful when a sudden demand for hot water or heating arises. Each mode can be selected via the front‑panel display using the Mode button. The boiler also supports a Schedule function, allowing users to programme heating and hot‑water periods for weekdays and weekends. Settings are adjusted with the Up and Down buttons, and confirmed with Enter. The thermostat can be set between 5 °C and 30 °C, with a default of 21 °C for heating and 55 °C for domestic hot water. The boiler automatically adjusts the water temperature based on the thermostat setting, ensuring consistent comfort while avoiding excessive energy use. The user interface displays the current mode, temperature, and fault status, providing real‑time feedback for optimal operation. Users can also set a maximum boiler pressure limit to protect the system from over‑pressure conditions. The boiler’s safety features include a pressure relief valve that opens at 1.5 bar, and a low‑water cut‑off that shuts the burner when water levels drop below 0.5 bar. For convenience, the boiler offers a quick‑start feature that reduces the warm‑up time to just a few minutes after power restoration. The display also shows fault codes, allowing users to identify and resolve issues before they become serious. Users should refer to the troubleshooting section for detailed guidance on interpreting fault codes and recommended corrective actions. The boiler’s flow sensor ensures that water temperature remains stable, preventing overheating and extending the lifespan of the heating system. Additionally, the user can monitor performance metrics via the companion app, which syncs data over Wi‑Fi and provides alerts for maintenance schedules.

Temperature and Thermostat Control
The Ideal Logic Combi 24 offers three primary operation modes: Eco, Comfort, and Boost. In Eco mode the boiler prioritises energy efficiency, running at a lower temperature and cycling more frequently to minimise consumption. Comfort mode delivers a higher water temperature for instant hot water and a warmer heating output, suitable for colder periods. Boost mode temporarily increases the boiler’s output for a short period, useful when a sudden demand for hot water or heating arises. Each mode can be selected via the front‑panel display using the Mode button. The boiler also supports a Schedule function, allowing users to programme heating and hot‑water periods for weekdays and weekends. Settings are adjusted with the Up and Down buttons, and confirmed with Enter. The thermostat can be set a maximum boiler pressure limit; if pressure exceeds 1.5 bar, the system will shut down to prevent damage. The system’s safety features include a pressure relief valve that opens at 1.5 bar and a low‑water cut‑off that shuts the burner when water levels drop below 0.5 bar. For convenience, the boiler offers a quick‑start feature that reduces the warm‑up time to just a few minutes after power restoration. The display also shows fault codes, allowing users to identify and resolve issues before they become serious.
Calibration of the thermostat is straightforward: press the Cal button until the display flashes, then adjust the setpoint using the Up/Down keys until the desired temperature is reached.
The system records the calibration offset and applies it to all subsequent readings.
For users with multiple rooms, the thermostat can be linked to a network of zone valves, allowing independent temperature control per zone.
Internal sensor tolerance ±0.5 °C.
Users can view the sensor status via the diagnostics menu, which displays current sensor voltage and temperature error.
If the sensor reports a fault, the boiler will enter a safe‑mode state, shutting the burner and displaying a fault code for troubleshooting.
The thermostat also supports a night‑time mode, reducing the setpoint by 2 °C during overnight hours to save energy without compromising comfort.
This mode can be scheduled through the timer function, which allows users to define start and end times for each day of the week.
The boiler’s firmware automatically adjusts the burner duty cycle to match the reduced setpoint, resulting in lower fuel consumption throughout the day.
For advanced users, the system offers a manual override that temporarily disables the thermostat, allowing the burner to run at full capacity during peak demand periods or when the boiler needs to pre‑heat the house before occupants return.
The override can be engaged by pressing the Override button and will remain active until the user cancels it or until the next scheduled cycle.
The thermostat’s LED indicator provides visual feedback: a steady light means the system is operating normally, a blinking light indicates a fault, and a flashing light signals that the system is in calibration mode.
Users should refer to the LED status guide in the manual for detailed meanings.
Finally, the boiler’s energy‑saving algorithm monitors room temperature trends and adjusts the burner output accordingly, ensuring that the heating system operates at peak efficiency throughout the day.

Boiler Cycling and Performance
The Ideal Logic Combi 24 employs a sophisticated cycling algorithm that balances rapid response with energy efficiency. During a heating cycle, the boiler ignites, reaches the set temperature, and then shuts off, allowing the water to retain heat within the distribution system. The cycle length typically ranges from 5 to 15 minutes, depending on ambient temperature and load demand. The short cycling time reduces standby losses and ensures that the boiler operates only when necessary. The system monitors the return water temperature and compares it to the desired setpoint. If the difference exceeds 0.5 °C, the burner re‑ignites; otherwise, the boiler remains off. This precise control prevents over‑heating and conserves fuel. In Eco mode, the boiler lengthens the off period, extending the cycle to 15 minutes or more, which lowers overall consumption. Comfort mode shortens the cycle to 5 minutes, delivering instant heat. Boost mode temporarily shortens the cycle to 2 minutes, providing a quick surge of heat for sudden demand. The boiler’s pressure sensor ensures safe operation; if the pressure rises above 1.5 bar, the system automatically shuts down to protect the unit. The boiler’s cycling performance is a key factor in delivering reliable heating while keeping energy costs low. Add 9.!!!
Timer and Scheduling Functions
The Ideal Logic Combi 24 timer and scheduling system lets users program heating periods for weekdays, weekends, and holidays. The front panel offers a 24‑hour clock, two schedules (A and B), and a holiday mode that overrides both schedules. Each schedule can have up to four heating periods per day, with start and end times selectable in 15‑minute increments. The boiler automatically adjusts to the setpoint when the timer activates, and a “boost” function shortens the off cycle for a quick surge of heat. The timer is powered by an internal real‑time clock that remains accurate after power interruptions, thanks to a backup battery. All scheduling data is stored in non‑volatile memory, so settings persist after a power outage. The timer also includes a “holiday” toggle that keeps the boiler running on a single schedule for the entire holiday period, simplifying management for extended trips. The timer supports 24‑hour and 12‑hour formats and can repeat daily. Users can set a maximum runtime per day. The boiler’s internal memory stores up to 30 days of history. The combination of flexible scheduling, energy‑saving modes, and remote control makes the Ideal Logic Combi 24 a convenient and efficient heating solution for modern households. The system also offers a reset function now.
Fault Codes and Error Messages
The Ideal Logic Combi 24 shows fault codes on its LCD. Each two‑digit code indicates a specific issue:
- 01 – Low water pressure: Check supply and gauge (1.0‑1.5 bar).
- 02 – High water temperature: Verify thermostat and limit.
- 03 – Faulty heating element: Inspect and replace if needed.
- 04 – Condensate pump failure: Clean or replace the pump.
- 05 – Airlock: Bleed radiators to restore flow.
- 06 – Low condensate temperature: Check return line for blockage.
- 07 – Sensor fault: Test and replace sensors.
- 08 – Boiler lockout: Reset by holding the reset button 5 s.
- 09 – Communication error: Verify wiring to control panel.
- 10 – Power supply fault: Check mains voltage and fuse.
- 11 – Low pressure sensor: Replace sensor.
- 12 – High pressure sensor: Replace sensor.
- 13 – Flow sensor fault: Check flow sensor and replace if needed.
- 14 – Boiler overheat: Check boiler temperature and reset.
When a fault appears, heating stops until the problem is fixed. Use the troubleshooting section or contact support. Regular monitoring keeps the boiler running efficiently.
For diagnostics, press the diagnostic button for 3 s to view real‑time sensor data. If the fault persists after reset, schedule a professional inspection to avoid safety hazards.
All fault codes are logged in the boiler’s memory for later review!!

Troubleshooting Common Issues
When the Ideal Logic Combi 24 fails to heat, follow these steps. First, check the power supply: ensure the mains voltage is 230 V and the fuse is intact. Next, verify the water pressure gauge reads between 1.0 and 1.5 bar; if low, refill the system. If the boiler displays fault code 01, bleed radiators to remove airlocks. For code 02, confirm the thermostat set‑point matches the desired room temperature and that the limit switch is not tripped. Code 03 indicates a heating element fault; inspect the element for burn marks and replace if necessary. Code 04 signals a condensate pump failure – clean the pump and check the return line for blockages. Code 05 suggests an airlock; bleed all radiators. Code 06 means condensate temperature is too low; check the return pipe for insulation or blockage. Code 07 points to a sensor fault; test the temperature and pressure sensors and replace them if readings are off. Code 08 is a boiler lockout; reset by holding the reset button for 5 s and ensure all safety interlocks are clear. Code 09 indicates a communication error between the control panel and boiler; verify wiring and connectors. Code 10 is a power supply fault; replace the mains supply or fuse. Code 11 and 12 refer to low and high pressure sensors respectively; replace the faulty sensor. Code 13 shows a flow sensor fault; inspect the flow sensor and replace if damaged. Code 14 indicates boiler overheat; allow the unit to cool and check the temperature sensor. If the problem persists after following these steps, schedule a professional service appointment. Regular maintenance and timely repairs prevent most issues and extend the boiler’s life. Check manual details now!

Routine Maintenance and Cleaning
Routine maintenance keeps the Ideal Logic Combi 24 efficient and extends its life. Follow this yearly checklist before heating season:
- Check water pressure (1.0–1.5 bar). Add water if low.
- Inspect condensate drain; clear blockages.
- Bleed radiators and boiler inlet.
- Wipe external surfaces for corrosion.
- Test safety valves and limit switches.
- Verify thermostat and temperature sensors.
- Clean air filter if fitted.
- Check for unusual noises or vibrations.
- Log all maintenance actions.
- Schedule professional inspection every two years.
During routine checks, also verify that the condensate pump is operating correctly by ensuring the condensate level in the pump chamber remains below the minimum mark. Inspect the return pipe for kinks or blockages that could restrict flow. Check the boiler’s external vent for any obstructions and ensure it is free of debris. If the boiler displays any fault code during operation, refer to the fault code list in the user manual and take corrective action promptly. Regularly inspect the boiler’s electrical connections for tightness and signs of wear. Keep the boiler’s surrounding area clear of flammable materials and ensure adequate ventilation.
Performing these steps regularly reduces downtime, improves fuel efficiency, and prevents costly repairs. If any abnormal behaviour occurs, consult troubleshooting or contact authorised service.
Manual handy

Warranty and Service Information
The Ideal Logic Combi 24 comes with a standard 5‑year limited warranty covering parts and labour for manufacturing defects. Warranty begins on the date of purchase and is valid only if the boiler is installed by an authorised installer and maintained according to the user guide. The warranty does not cover damage from misuse, accidental damage, or failure to perform routine maintenance.
The warranty covers manufacturing defects only. It excludes damage due to misuse, accidental damage, or failure to perform routine maintenance. The warranty is void if the boiler is not installed by an authorised installer or if it is altered or repaired by unauthorised personnel.
Service is available through the manufacturer’s network of certified technicians. To request service, contact the nearest service centre using the phone number or email listed in the installation manual; All service calls are logged and a service report is provided. If the boiler is still under warranty, the repair will be performed at no cost to the customer, provided the fault is covered by the warranty terms.
After the warranty expires, a standard maintenance contract can be purchased. This contract includes annual inspections, priority service, and discounted parts. For more information, visit the manufacturer’s website or contact the customer support team. Keep the warranty card and service records in a safe place for future reference. All warranty and service information is also available in the user manual on the web site online

Compliance and Regulations in the united kingdom
The Ideal Logic Combi 24 meets all current UK and EU safety and environmental regulations. It bears the CE mark, confirming conformity with EU directives, and the UKCA mark, ensuring compliance with the UK’s new regulatory framework. The boiler complies with BS EN 60335‑1 and BS EN 60335‑2‑19, covering household electrical appliances and heating equipment safety. It satisfies the UK’s Energy Savings Opportunity Scheme (ESOS) requirements, providing the energy efficiency data needed for statutory reporting. Emissions comply with the latest UK Environmental Permitting Regulations, keeping CO₂ and NOₓ levels within limits set by DEFRA. The unit is listed on the National Energy Efficiency Register (NEER) and is eligible for the Boiler Upgrade Scheme, offering grants for replacing older units. Installation must be carried out by a registered Gas Safe engineer and inspected annually by a qualified professional to maintain compliance. All service and maintenance records should be kept for at least five years, as required by the HSE guidelines. For further details, consult the user manual or the manufacturer’s website. The boiler’s compliance ensures safe operation, environmental responsibility, and eligibility for government incentives across the united kingdom. The boiler also meets the UK Building Regulations Part L, guaranteeing energy efficiency in new and existing buildings. All test certificates are available through the manufacturer’s secure portal, allowing regulatory audits and ensuring traceability. This compliance supports home integration.
Contact Support and Resources
For assistance with the Ideal Logic Combi 24, users can access multiple support channels. The manufacturer’s dedicated helpline operates Monday to Friday, 8 am–6 pm (UK time), reachable at +44 20 1234 5678. A comprehensive FAQ and troubleshooting guide is available on the official website, www.ideallogic.co.uk/support, providing step‑by‑step solutions for common faults and error codes. For firmware updates, log in to the user portal and download the latest version; the installer will guide you through the update process. If you require a service visit, schedule an appointment online or call the helpline. All service engineers are Gas Safe registered and trained on the latest BS EN 60335‑2‑19 safety standards. For warranty claims, submit a claim form via the portal; the claim will be processed within 7 business days. Technical documentation, including wiring diagrams, user manuals, and compliance certificates, can be downloaded from the resources section. For regulatory compliance queries, contact the UK Compliance Office at compliance@ideallogic.co.uk. The company also offers a live chat feature on the website, available 24/7, to answer quick questions. Finally, community forums hosted by the manufacturer allow users to share experiences and solutions. All support materials are available in both English and Welsh to accommodate local users.
Additionally, the manufacturer hosts quarterly webinars covering advanced diagnostics, maintenance best practices, and regulatory updates. These sessions are recorded and archived for future reference. Users can register via the website or request a recording if they miss a live session. For bulk purchases or commercial installations, a dedicated account manager is assigned to streamline procurement, installation, and after‑sales support. All communications are logged and can be accessed through the customer portal for transparency. The support team is committed to resolving issues within 48 hours, ensuring minimal downtime. Feedback is encouraged through the post‑support survey, which helps improve product quality and service delivery. The company also maintains a knowledge base with articles on energy efficiency, boiler cycling, and eco‑friendly operation. This resource is updated monthly to reflect the latest industry standards and best practices. Users are encouraged to review these materials regularly to maximize performance and compliance.
Support staff are fluent in English and trained!